How can I quickly define the sample types in the fragment analysis tab?

in Fragment Analysis

This article is part of the Coffalyser.Net Tips & Tricks collection.

For proper analysis of an MLPA experiment with Coffalyser.Net, it is important to correctly define the sample type for each sample in the fragment analysis tab. If you have many samples, this can be time-consuming. Two methods can speed up this step: selection of sample types using only the keyboard, and automatic detection of sample types by Coffalyser.Net.

Selecting samples using the keyboard

After clicking the sample type column of a sample, the sample type can quickly be selected by pressing the first letter of the sample type. After pressing this letter, you can select other samples with the up or down arrow keys to repeat the process.

Sample typeLetter to press
SampleS
Reference sampleR
Positive referenceP
No DNAN
Digested sampleD

Automatic detection of sample types

Coffalyser.Net is able to automatically define sample types based on keywords in the sample name. To use this functionality, right-click and select Auto Recognize Sample Types or press the keyboard shortcut Ctrl + Shift + R.

The table below lists which keywords are recognized as which sample types. All samples without one of these keywords are recognized as sample.

Sample typeTerm(s)
Reference sampleREF; ref; reference
Positive referencePOS; pos; positive
No DNANoDNA
Digested sampleDIG; dig; digested

You can see this automatic sample type detection in action in the short video below.

  • Tags
  • Coffalyser.Net

Related Pages

  • Video: How to analyse MS-MLPA data in Coffalyser.Net
  • Video: How to perform MLPA data analysis for copy number determination in Coffalyser.Net

Rate the quality of this page

This page was helpful :) :( This page was not helpful

1 of 2 people found this page helpful

If you have any comments or suggestions on this article, please send us your feedback.

Disclaimer

The information provided in this material is correct for the majority of our MLPA products. However, for certain applications, the instructions for use may differ. In the event of conflicting information, the relevant instructions for use take precedence.


Quick Jump
  • « MLPA.com
  • Support Home
  • Knowledgebase
  • News
  • Downloads
  • Contact Us
Top
Privacy Policy | Terms and Conditions | Contents copyright © 2019 MRC-Holland